Jabsco
Pump Mini Puppy 12V 1.6Gpm - 18620-0003 - 6-186200003F1
Includes an integral on/off/reversing switch to change direction of flow. Use for circulating and draining bait tanks, changing engine oil, or general pumping. Ports are 3/8" NPT internal and GHT external. Impeller is 14500003. NOT TO BE USED IN POTABLE WATER SYSTEMS.
Pump 12V-Com-Duty Water Puppy - 18670-0123 - 6-186700123F1
This bronze body, self-priming impeller pump will produce a dry prime suction lift of about 6' and has a maximum head of 20'. Use for bilge pumping, livewell circulation, washdown, and general pumping applications. Cannot be run dry. Permanent magnet type motor is fully enclosed with a stainless steel shaft and has adequate torque to reverse the pump. Complies with USCG Electrical Standards 183.410 and ISO 8846 marine for ignition protection on gasoline powered vessels. Ports: 1/2" internal pipe threads, 1" external hose barb & 3/4" external garden hose adapter.
Pump 115Vac 9.5 Gpm - 11810-0003 - 6-118100003F1
This portable, self-priming pump features a bronze pump head, continuous duty 1/3hp motor with thermal over-load protection, and more. Suitable for bait tank circulation, oil transfer, washdown, and utility dock pump. Dry self-priming up to 7.8' with a maximum head of 40'. 8' power cord and convenient handle. Includes nitrile oil resistant impeller. NOT TO BE USED IN POTABLE WATER SYSTEMS.
Pump 115 Volt Water Puppy - 12210-0001 - 6-122100001F1
This portable, self-priming pump features a bronze pump head. Handles hard and soft solids without clogging. Suitable for washing down decks and docks, water for ship's service supply, or pumping out crankcase oil. Dry self-priming up to 4.9' with a maximum head of 40'. Replaceable brushes, 6' power cord and nitrile oil resistant impeller. Includes garden hose thread adapter. NOT TO BE USED IN POTABLE WATER SYSTEMS.
Pulley Driven Flexible Impeller Pump - 7420-1001 - 6-74201001F1
Mid-size pump with vertical oriented ports. Self-priming to 10 ft vertical liftFull thickness cam, mechanical seal, short stainless steel shaftNeoprene impeller,Marine engine cooling for engine models: caterpillar 3160. caterpillar 3208.
Pulley Driven Engine Cooling Pump W/Nitrile Impeller - 777-9003 - 6-7779003F1
Flexible impeller pumps are self-priming to 10' and are ideal for engine cooling, wash-down, circulation, and many general purpose on-board or dockside applications. The bronze bodies and stainless steel shafts are suited for the marine environment and can operate in either rotational direction. Different port orientations available to meet various pumping requirements. Most models have replaceable cams and wearplates for extended life.
Pulley Driven Engine Cooling Pump W/Neoprene Impeller - 777-9001 - 6-7779001F1
Flexible impeller pumps are self-priming to 10' and are ideal for engine cooling, wash-down, circulation, and many general purpose on-board or dockside applications. The bronze bodies and stainless steel shafts are suited for the marine environment and can operate in either rotational direction. Different port orientations available to meet various pumping requirements. Most models have replaceable cams and wearplates for extended life.
Pulley Driven Engine Cooling Pump - 2620-1101 - 6-26201101F1
Self priming flexible impeller pump. Ideal for engine cooling, washdown, circulation and other general purposes. Corrosion resistant bronze bodies and stainless shafts are well suited for marine environments. Permanently lubricated ball bearings.
Par Service Kit - 37182-0000 - 6-371820000F1
Please call our Sales Department for complete ITT spare parts stock and information.SPARE PARTS that are stock items are listed below for Jabsco bilge pumps.
Par Service Kit - 30124-0000 - 6-301240000F1
Please call our Sales Department for complete ITT spare parts stock and information.SPARE PARTS that are stock items are listed below for Jabsco bilge pumps.
Par Service Kit - 30101-0000 - 6-301010000F1
Please call our Sales Department for complete ITT spare parts stock and information.SPARE PARTS that are stock items are listed below for Jabsco bilge pumps.
Par 5 12V Sealed Beam Replacement Bulb - 67296-0000 - 6-672960000F1
Par 24V Blower Flangemount 4 - 35400-0010 - 6-354000010F1
Offers safe, efficient and have high volume evacuation of hazardous vapors on vessels equipped with gasoline powered engines. Satisfy requirements of USCG regulation Title 46, Chapter I, part 183, subpart K for marine ventilation when properly installed and used. BIA type accepted. Also exhausts warm air from galleys and engine rooms, ventilating steam or odors from heads and general marine air circulation. Constructed of tough reinforced plastic housing and one-piece balanced rotor for maximum corrosion resistance. Flangemount blowers are generally mounted with discharge port fastened directly to flat external surface minimizing required ducting. Inlet port can be connected with duct hose to area requiring ventilation.
Par 12V Toilet Conversion Kit - 37010-0092 - 6-370100092F1
Converts manual toilet to simple pushbutton electric operation without the need to alter existing inlet or discharge seacocks. Comprehensive kit has all necessary parts, including flushing pump, macerator pump, switch, adapters, clamps, hose and fastenings.
Par 12V Conversion Kit 25Amp - 29200-0120 - 6-292000120F1
Easily converts all PAR manually operated toilets to convenient electric operation. Complete for 29090/2910 series. Existing discharge plumbing remains undisturbed for ease of installation. Inlet port fits 3/4" hose. 10 to 12" high, 4" wide, 7-3/4" deep. Fuse size 25. 24 amp draw.
Par 12V Blower Flangemount - 34739-0010 - 6-347390010F1
Offers safe, efficient and have high volume evacuation of hazardous vapors on vessels equipped with gasoline powered engines. Satisfy requirements of USCG regulation Title 46, Chapter I, part 183, subpart K for marine ventilation when properly installed and used. BIA type accepted. Also exhausts warm air from galleys and engine rooms, ventilating steam or odors from heads and general marine air circulation. Constructed of tough reinforced plastic housing and one-piece balanced rotor for maximum corrosion resistance. Flangemount blowers are generally mounted with discharge port fastened directly to flat external surface minimizing required ducting. Inlet port can be connected with duct hose to area requiring ventilation.
Par 12V 3 Blower Flexmount - 36740-0000 - 6-367400000F1
Offers safe, efficient and have high volume evacuation of hazardous vapors on vessels equipped with gasoline powered engines. Satisfy requirements of USCG regulation Title 46, Chapter I, part 183, subpart K for marine ventilation when properly installed and used. BIA type accepted. Also exhausts warm air from galleys and engine rooms, ventilating steam or odors from heads and general marine air circulation. Constructed of tough reinforced plastic housing and one-piece balanced rotor for maximum corrosion resistance. Flexmount blowers have both inlet and outlet ports designed for slip-on flexible duct connections and are ideal when an in-line installation of blower is preferred. May be rotated in bracket to permit installation with discharge port in any direction.
Mini Accumulator Tank - 30573-0003 - 6-305730003F1
Tank is intended for installation in any pumped water system controlled by a pressure switch and can serve as a storage vessel as well as a pulsation dampener. By smoothing water flow and reducing on/off switch cycling of the pump the result is quieter operation and longer pump life. The even flow of water gives better control of hot water temperature with systems using instant water heaters. Easily fitted to new or existing systems with quick connect fittings. Mounting point for optional pressure switch. Internal bladder. Manufactured from food grade materials, NSF Standard 18 listed.
Mag Drive Centrifugal Pump - 436977 - 6-436977F1
Designed for applications that require a safe and leak free, continuous duty pump. Great for marine air conditioning circulation, ice makers, hot water circulation, livewell and bait tank installations. Pump head is manufactured in chemical resistant thermoplastics - entirely non-metallic. UL listed, ignition and thermally protected fan cooled motor.